If you’ve ever worked with a chemical tower—whether as a plant operator, process engineer, or maintenance lead—you’ve probably dealt with entrainment without even realizing it. Entrainment, the carryover of liquid droplets or solid particles from the tower’s internal stages (trays, packing, etc.) into the overhead gas stream, isn’t just a minor nuisance. It erodes equipment, contaminates downstream products, increases operational costs, and even poses safety risks in some processes. As a chemical tower supplier with decades of hands-on experience designing, manufacturing, and installing towers for refineries, petrochemical plants, and specialty chemical facilities, I’ve seen firsthand how a small entrainment issue can snowball into a major operational headache. In this post, I’ll break down what causes entrainment in chemical towers, share practical, science-backed strategies to reduce it, and explain how our team tailors these solutions to fit your specific process needs. Chemical Tower

First, let’s get clear on what entrainment is and why it matters. Chemical towers operate by bringing vapor and liquid into intimate contact—either across trays (sieve, valve, bubble cap) or through structured/random packing—to separate components via distillation, absorption, or stripping. For this contact to work efficiently, the vapor rising through the tower must move upward without stripping liquid droplets off the trays or packing, and the liquid flowing downward must settle without being carried away by the vapor. When that balance breaks, entrainment occurs. The droplets that get carried over can clog downstream compressors, foul heat exchangers, reduce product purity (critical for pharmaceuticals, for example, where even trace contaminants can ruin batches), and force frequent shutdowns for maintenance. In one recent project with a mid-sized specialty chemical plant, their original tower had 8% entrainment, which meant they were losing 2,000 gallons of valuable solvent daily and replacing a compressor every 18 months. By adjusting entrainment controls, we cut entrainment to 1.2% and extended compressor life to 7 years—saving them over $500,000 annually in downtime and replacement costs.
So what causes entrainment in the first place? The main driver is excessive vapor velocity in the tower’s active section. When vapor rises faster than the liquid can drain back down through the tray/packing, it creates a turbulent force that picks up liquid droplets. This is called flooding, a extreme form of entrainment that renders the tower ineffective. But it’s not just high velocity—mismatched tower design, improper tray or packing selection, poor distributor design, and even fouling over time can contribute. For example, a plant that upgraded its feed rate without adjusting the tower’s internal components will almost certainly see increased entrainment, because the internals were sized for a lower vapor load. Similarly, if a liquid distributor is poorly designed, it may not spread liquid evenly across the tray, creating stagnant zones where liquid accumulates and gets easily entrained by vapor.
Now, let’s dive into the actionable strategies to reduce entrainment, many of which we integrate into our tower designs as standard features, not afterthoughts.
First and foremost: Size vapor velocity correctly for your tower’s active section. This is the single most impactful step to prevent excessive entrainment. The key here is working within the “loading range” of your tower—an operational sweet spot where vapor velocity is high enough to ensure good vapor-liquid contact, but low enough to avoid carrying over liquid. The loading range is specific to your tower’s internal type: sieve trays, for example, typically have an optimum vapor velocity of 0.3 to 0.8 m/s, while structured packing might have a slightly lower range (0.2 to 0.6 m/s) due to their smaller flow channels. How do you get this right? It’s not just using a generic formula off the internet. We conduct a detailed process audit of your feed rate, composition, temperature, and pressure, then use computational fluid dynamics (CFD) modeling to simulate vapor flow through the tower’s cross-section. This lets us avoid “over-sizing” the tower (which wastes capital) or “under-sizing” it (which leads to excessive velocity and entrainment). In a 2022 project with a natural gas processing plant, their original tower was sized for a 10% higher feed rate than their current operation, leading to 6% entrainment. We re-calibrated the tower’s flow distribution using CFD and adjusted the tray orifice size to lower optimal vapor velocity by 12%, cutting entrainment to 0.9% without reducing separation efficiency.
Second: Install or upgrade entrainment separators at the tower’s overhead outlet. Even with perfect vapor velocity, some small droplets will form, which is where entrainment separators come in. These devices are designed to capture and coalesce liquid droplets before they leave the tower, so they can drain back down into the tower’s base. The two most common types are demister pads and cyclone separators, each with their own use cases. Demister pads are made of knitted metal or plastic wire mesh, and work by forcing vapor to weave through the mesh, where droplets collide with the wires, coalesce into larger drops, and fall into the liquid sump. They’re cost-effective, low-profile, and ideal for small to medium droplet sizes (10 to 100 microns). Cyclone separators, on the other hand, use centrifugal force to spin vapor and throw droplets against the wall of the separator, where they drain back. They’re more efficient for larger droplets, can handle higher temperatures and pressures, and are better for applications where fouling is a concern (since demister pads can get clogged with solid particles over time). Our team doesn’t just pick one off the shelf—we match the separator type to your process. For a distillation tower producing ethanol, where small liquid droplets can contaminate the overhead vapor, we use a combination: a demister pad at the base of the overhead line for fine droplets, paired with a small cyclone for larger, heavier carryover. For a high-temperature stripping tower in a refinery, we use a stainless steel cyclone to avoid fouling from heavy hydrocarbons. A quick note: improper installation of separators can reduce their effectiveness by 50% or more. We align demister pads so that vapor flows perpendicular to the mesh, not at an angle, and size cyclones to match the tower’s overhead vapor flow rate to avoid re-entrainment of captured droplets.
Third: Optimize the tower’s internal components (trays, packing, distributors) to reduce liquid carryover. Entrainment starts at the point where liquid and vapor interact, so making sure these internals are properly selected and installed is critical. For trays, using valve trays instead of sieve trays can help reduce entrainment, especially at varying flow rates. Valve trays have movable valves that adjust to vapor load—when vapor is low, the valves close slightly to maintain high enough velocity for good contact, and when vapor is high, the valves open to allow vapor to pass through without creating excessive turbulence that picks up liquid. Sieve trays, while cheaper, are more prone to entrainment at high loads because their fixed orifices can create sudden, high-velocity jets of vapor. For packing, structured packing is generally more resistant to entrainment than random packing, because it has uniform, orderly channels that promote even vapor flow and avoid the turbulent, mixed flow of random packing. We also pay close attention to liquid distributors, which are often overlooked but can be a major source of entrainment. A distributor that sprays liquid unevenly across the tray will create areas where liquid is too thick, leading to easy carryover, or too thin, reducing separation efficiency. We design distributors with precise orifice sizes and spacing to deliver uniform liquid distribution within 5% across the entire tower cross-section. In one case, a chemical plant’s tray tower had uneven liquid distribution due to a 10-year-old distributor that was clogged with scale. We replaced it with a modular distributor that can be easily cleaned, and reduced entrainment by 3.5% just from that change.
Fourth: Maintain your tower regularly to prevent entrainment buildup over time. Entrainment isn’t a “set it and forget it” issue—it worsens with fouling, corrosion, and mechanical wear. Over time, scale, salt deposits, or polymer build-up can narrow the flow passages in trays or packing, increasing vapor velocity and leading to higher entrainment. Corroded trays or broken packing can create uneven flow paths, causing turbulent vapor that picks up liquid. Regular maintenance checks—including inspection of tray orifices, cleaning of distributors and separators, and replacement of worn components—can catch these issues before they lead to severe entrainment. We recommend a quarterly visual inspection of the overhead line and separators, and a full internal tower inspection every 12 to 18 months. For plants with high fouling processes (like wastewater stripping or heavy oil distillation), we offer optional periodic cleaning services for separators and internals, which we’ve found reduces annual entrainment spikes by up to 25% compared to plants that only do reactive maintenance.
A common question we get is: How do I know if my tower has excessive entrainment? There are a few telltale signs, and some that require testing. Visible carryover in the overhead vapor (if you can see liquid droplets in the line), a sudden drop in separation efficiency (where product purity is lower than design specs), increased pressure drop across the tower (caused by liquid clogging trays/packing), and higher utility costs (since you’re using more energy to push vapor through the tower) are all red flags. For a more precise measurement, we can perform a simple entrainment test using a liquid-vapor sample probe installed in the overhead line. The probe captures a sample of the vapor, separates the liquid droplets, and lets you quantify the entrainment rate—this is how we determined that plant I mentioned earlier had 8% entrainment, which was far above the acceptable 1 to 2% for their process.
Now, let’s talk about how our chemical tower solutions address these entrainment issues, because as a supplier, our goal isn’t just to sell you a tower—it’s to make sure it operates efficiently for years. We don’t use a one-size-fits-all design. For example, if you have a process with variable feed rates, we’ll spec valve trays with flexible valve sizing and a multi-stage entrainment separator that works across different vapor loads. If you’re working with a high-purity product, like pharmaceutical intermediates, we’ll use polished stainless steel internals to avoid fouling and a dual-stage separator (demister + cyclone) to capture even the smallest droplets. We also offer retrofitting services for existing towers—you don’t have to replace your entire tower to fix entrainment. We can upgrade internals, install new separators, adjust flow distribution, and re-size vapor passages, often with minimal downtime. In a 2021 retrofitting project with a fertilizer plant, they had an old tray tower with 7% entrainment, and we retrofitted it with new valve trays and a cyclone separator, all during a 5-day plant shutdown. The entrainment dropped to 1.1%, and they saved over $300,000 annually in lost ammonia product.
I want to be clear: entrainment is a solvable problem, but it requires a combination of proper design, careful component selection, and regular maintenance. Too often, plants try to “tough it out” with a tower that was improperly sized or designed, leading to avoidable costs. As someone who’s worked with chemical towers for over 20 years, I’ve seen that the most successful operations are the ones that partner with a supplier who understands not just the design specs, but the real-world challenges of their process.

If you’re experiencing excessive entrainment in your chemical tower, or you’re designing a new tower and want to make sure entrainment is addressed from the start, we’re here to help. We offer free process audits and entrainment assessments to identify the root cause of your issue, and we’ll work with you to develop a tailored solution that fits your budget and operational needs. Don’t let entrainment continue to eat into your profits or disrupt your operations. Reach out to our team to start a conversation about your chemical tower needs.
Stainless Steel Reactor References
- Chen, G. T., “Distillation Design and Control Using Aspen Simulation,” Wiley, 2018, Chapter 5: Entrainment and Flooding in Tray Towers.
- Kister, H. Z., “Distillation Operation,” McGraw-Hill, 1992, Chapter 8: Entrainment Separation and Internal Design.
- Smith, B. D., “Design of Equilibrium Stage Processes,” McGraw-Hill, 1963, Chapter 6: Vapor-Liquid Contact and Carryover.
- American Institute of Chemical Engineers (AIChE), “Entrainment in Gas-Liquid Contactors,” 2005, Industrial Practice Series.
Zibo Gyro Industry Engineering
As one of the most professional chemical tower manufacturers and suppliers in China, we have world-leading production equipment and strong manufacturing capabilities. Please feel free to wholesale advanced chemical tower at competitive price from our factory. Customized orders are welcome.
Address: Jinling San Village, East of Qilu Chemical Industrial Park, Linzi District, Zibo City, Shandong Province